No. 3 – How to Bump test GasAlertMicroClip XL

How-to-bump-test-a-MicroClip-XL.jpg

Bump test GasAlertMicroClip XL What is Bump test a gas detector? Bump test is checking responsibility of gas sensors and alarm trigger checking. Why need Bump test? We need ensure that detector still work well before use, because it is safety equipment. Almost maker recomment user doing Bump test each day before use. Prepare for

More

No. 2 – Turn ON/OFF 4 gases detector GasAlertMicroClip XL

No-2.-Bat-Tat-GasAlertMicroClip-XL.jpg

Turn ON/OFF 4 gases detector GasAlertMicroClip XL Generally, Turn ON/OFF a 4 gases detector are the same way, only manipulation are diffrent between a maker The general principle of turning on a gas detector is as follows: Fully charging before use. If low battery, some function may work in-correct. Press and hold Power button until unit

More

BW GasAlertMax XT II – No.2: Instruction for use video

Huong-dan-su-dung-BW-GasAlertMax-XT-II.jpg

GasAlertMax XT II – Instruction for use BW GasAlertMax XT II can be detect 4 gases: LEL/O2/CO/H2S simultaneously BW GasAlertMax XT II integated internal pump for Confined space function up to >20m Each Turn ON time, this portable gas detector required pump test by block pump then un-block pump. If pump work well, it indicated PUMP

More

MSA Altair 4XR gas detector: Video 7 – Motion Alert

MAH02826-Kiem-tra-motion-Public.jpg

MSA Altair 4XR – Motion Alert To activate or deactivate the Motion Alert feature, press the “UP” button while the Motion Alert Activation page is displayed. When the Motion Alert feature is active, the Motion Alert symbol will flash every 3 seconds. The device will enter pre-alarm when no motion is detected for 20 seconds. This

More

MSA Altair 4XR gas detector: Video 6 – Calibration

MAH02824-Hieu-chuan-Public.jpg

Calibration MSA Altair 4XR Prepare calibration equipment: A MSA Altair 4XR gas detector (Normal operation) Gas cylinder with correct type of gas inside Valve regulator Tubing (normally, supply with gas detector) Calibration cap (normally, supply with gas detector) Processing calibration: Step 1: Assemby valve regulator and tubing to Gas cylinder Step 2: Active calibration function

More

MSA Altair 4XR gas detector: Video 3 – Setting up

MAH02819-Huong-dan-cai-dat-Public.jpg

Setting up for MSA Altair 4XR Fully understanding a equipment before use always the most importance. Video below will be instruct user how to setting up almost parameter inside MSA Altair 4XR ie: Sensor settup, Calibration settup, Alarm settiup… Some parameters need quality person, who really deepply understand this unit and safety standards for setting

More