Gas Generators designed and engineered for GC laboratory applications, the Precision series represents the cutting-edge of Peak Scientific innovation in on-demand gas generator design. Combining convenience and reliability in a stackable, modular and compact design, Precision is the safe and practical choice for your GC instrument gas requirements.
CAC-Precision Hydrogen
- Max Flow Rate: 100cc/Phút, 200cc/Phút, 300cc/Phút, 450cc/Phút
- Max Pressure: 100psi/6.9bar
- Purity: 99.9995%
- Operating Temperature: 10°C – 35°C / 50°F – 95°F
- Water Purity Requirement: <1.0µ Siemens/cm hoặc >1 Mohm-cm
- Generator Dimensions (WxDxH): 38.0x 54.0 x 40.6cm / 14.9 x 21.2 x 15.9”
- Generator Weight: 31 Kg (68.3 lbs)
- Noise Level: Silent in operation
CAC-Precision Hydrogen 1200
- Max Flow Rate: 1200cc/min
- Max Pressure: 100psi / 6.9 bar
- Purity: 99.9995%
- Operating Temperature:10°C – 35°C / 50°F – 95°F
- Water Purity Requirement:<1.0µ Siemens/cm OR >1 Mohm-cm
- Generator Dimensions (WxDxH): 38.0x 54.0 x 40.6cm / 14.9 x 21.2 x 15.9”
- Generator Weight:31.5Kg (69.5 lbs)
- Noise Level: Silent in operation
CAC-Precision Hydrogen Trace
- Max Flow Rate: 250 cc/min, 500 cc/min, 1200 cc/min.
- Max Pressure: 100psi / 6.9 bar
- Purity: 99.99999%
- Operating Temperature:10°C – 35°C / 50°F – 95°F
- Water Purity Requirement:<1.0µ Siemens/cm OR >1 Mohm-cm
- Generator Dimensions (WxDxH): 406 x 380 x 540 mm / 16 x 15 x 21.3’’
- Generator Weight:29 Kg (64 lbs.) for 250 cc/min, 500 cc/min; 38 Kg (83.8 lbs.) for 1200 cc/min.
- Noise Level: Silent in operation
CAC-Precision Hydrogen SL
- Max Flow Rate: 100cc/min, 200cc/min
- Max Pressure: 100psi / 6.9 bar
- Purity: 99.9995%
- Operating Temperature:10°C – 35°C / 50°F – 95°F
- Water Purity Requirement:<1.0µ Siemens/cm OR >1 Mohm-cm
- Generator Dimensions (WxDxH): 250 x 160 x 355 mm / 9.9 x 6.3 x 14’’
- Generator Weight: 8Kg (17.7lbs)
- Noise Level: Silent in operation
CAC-Precision Nitrogen
- Max Flow Rate: 250cc/min, 600cc/min, 1.000cc/min
- Max Pressure: 100psi / 6.9 bar
- Purity: 99.9995%
- Operating Temperature:10°C – 35°C / 50°F – 95°F
- Water Purity Requirement:<1.0µ Siemens/cm OR >1 Mohm-cm
- Generator Dimensions (WxDxH): 38.0 x 54 x 25.6 cm / 14.9 x 21.2 x 10”
- Generator Weight: 21 Kg (250cc/min), 21 Kg (600cc/min), 26 Kg (1.000cc/min)
- Noise Level: Silent in operation
CAC-Precision Zero Air
- Max Flow Rate: 1.5L/min, 3.5L/min, 7L/min, 18L/min, 30L/min
- Operating Temperature:10°C – 35°C / 50°F – 95°F
- Generator Weight: 16 Kg (1.5L/min, 3.5L/min), 25kg (7L/min, 18L/min), 41 Kg (30L/min)
- Noise Level: Silent in operation
- Start-Up Time For Purity: 60 minutes
- Gas Outlets: 1 x 1/4″ BSPP
- Hydrocarbon Concentration (as Methane): <0.05ppm
CAC-Precision Air Compressor
- Flow Rate: suitable for various Precision combinations.
- Max Pressure: 120 psi /8.27 ba
- Operating Temperature:10°C – 35°C / 50°F – 95°F
- Generator Dimensions (WxDxH): 38.0cm x 54.0 cm x 40.6cm / 14.9” x 21.2” x 15.9”
- Generator Weight: 42 Kg / 93 lbs
- Gas Outlets: 1 x 1/4” BSPP
CAC-TOC 1500HP – Total Organic Carbon Generator
Peak Scientific’s TOC range of specialist generators have been designed specifically to supply clean, dry, carbon dioxide and methane free air for Total Organic Carbon analyzers.
Delivering carrier or combustion gas from an external air supply, these generators are available in two models, depending on your requirement, the standard model is suitable for non-purgeable organic carbon (NPOC) whilst the HP model is suitable for TC-IC process Total Organic Carbon analyzers.
Key Features:
- Produces clean, dry, hydrocarbon and carbon dioxide free air
- Ideal for TC-IC process TOC analyzers
- Performs 24/7 if needed
- Few moving parts means little maintenance required and ensures long life of the generator
- Completely silent in operation
- Minimal set-up required
- Can be supported by Precision Air Compressor
- 12 month comprehensive on-site warranty
CAC-TOC 1000 – Carrier/Combustion Gas Generator For TOC Analyzers
The TOC 1000 has been engineered using the latest in PSA and air catalyst technology to supply clean, dry, CO2 and hydrocarbon-free air for Total Organic Carbon analyzers using combustion catalytic oxidation.
The TOC 1000 provides a consistent and continuous supply of carrier and combustion air for TC, IC, TOC and NPOC analysis from a compact, bench-top system. Meeting the purity requirements of all combustion-type TOC analyzers, Peak Scientific’s TOC 1000 can support up to 5 TOC instruments with a maximum output of 1000cc/min.
With no internal compressor, the TOC is effectively silent in operation, requiring house air or an external compressor for operation.
Key Features:
- 1000cc TOC-grade Air @ 50psi outlet pressure
- <1ppm CO2, <0.05ppm CH4, <0.1ppm NOx/Sox
- Tested & approved by leading TOC instrument manufacturers
- Plug and play supply for TOC instruments with minimal set-up required
- Can operate 24/7 with no compromise on performance
- NPL (National Physical Laboratory) validated performance of catalytic chamber
- Space-saving small bench-top form factor
- Virtually silent in operation
- 2-year comprehensive warranty