MON-SAT 8.00 - 18.00.SUNDAY CLOSED
Hotline / Zalo: 033 44 13586
Stay connected:
Close
MON-SAT 8.00 - 18.00.SUNDAY CLOSED

MSA Altair 5X Gas Detector up to 6 gases

36,500,000

Description

Option up to 6 gases in gas listed below:

  • MSA Altair 5X detect LEL
  • MSA Altair 5X detect O2
  • MSA Altair 5X detect CO
  • MSA Altair 5X detect H2S
  • MSA Altair 5X detect SO2
  • MSA Altair 5X detect Cl2
  • MSA Altair 5X detect NH3
  • MSA Altair 5X detect PH3
  • MSA Altair 5X detect *HCN
  • MSA Altair 5X detect ClO2
  • MSA Altair 5X detect NO2
  • MSA Altair 5X detect CO2
  • MSA Altair 5X detect CO2
  • MSA Altair 5X detect CH4
  • MSA Altair 5X detect C3H8
  • MSA Altair 5X detect C3H8
  • MSA Altair 5X detect C4H10
  • MSA Altair 5X detect *C4H10
  • MSA Altair 5X detect TVOC (VOCs)

MSA ALTAIR 5X Gas Detector measures up to 6 gases including natural gas. Now available with a PID Detector.

The ALTAIR 5X Gas Detector is capable of measuring up to 6 gases simultaneously and is now available with integrated PID sensor for VOC detection. Driven by advanced MSA XCell® Sensor Technology,  the ALTAIR 5X Gas Detector delivers  faster response time, better stability, accuracy, longer service life, and cost savings over the life of the instrument.

Highlights

  • Detects combustible gases in LEL and/or volume percentage range, oxygen, carbon monoxide, carbon dioxide, hydrogen sulfide, sulfur  dioxide, ammonia, chlorine, VOCs,  and many others depending upon sensor configuration.
  • Rugged overmolded polycarbonate housing provides unsurpassed durability, including ability to survive 10-ft. (3m) drop; IP65-certified.
  • Field-proven integral pump provides consistent gas flow, eliminating concerns of externally-attached components.
  • High performance XCell Sensors last longer:
  • Typical life greater than 4 years for combustible, O2, CO/H2S, SO2, CO/NO2 and CO (high concentration) sensors.
  • Typical life greater than 3 years for NH3 and Cl2 sensors.
  • Most sensor response and clear times <15 seconds.
  • Less calibration gas used:
  • Requires about half of test gas typically used for calibration and bump tests.
  • Rapid bump test gives results in less than 10 seconds for most common sensor configurations.
  • Span calibration time of 60 seconds for most common sensor configurations.
  • MotionAlert feature option tells others that user has become immobile.
  • InstantAlert feature provides manual alarm to alert others as to a potentially hazardous situation.
  • PID option allows for accurate, reliable VOC response with programmable reference factors.
  • Large buttons and bright display provide easy operation, even when users wear gloves.
  • Exclusive end-of-sensor warning cautions users when unit’s sensor nears end-of-life.
  • Versatile MSA Link™ Software allows users to transmit data to a computer.
  • Compatible with GALAXY® GX2 Test System and MSA Link Pro Software for fleet management.
  • Wireless bluetooth included standard.
  • Markets: Contractor, Fire Service, Industrial, Oil & Gas, Utilities
  • Applications: Combustible Detection, Toxic Detection, Oxygen Detection, Confined Space

Specification

Altair 5 Specifications

Drop test6 feet
HousingRugged rubberized armor
Weight1 lb, 1.15 lb. (with IR sensor)
Dimensions (L x W x D)6.68″ x 3.52″ x 1.95″ (rechargeable, pumped, with belt clip)
6.68″ x 3.52″ x 1.65″ (rechargeable, diffusion, no belt clip)
Audible alarm>95 dB at 1 ft
Visual alarm2 ultra-bright LEDs
Vibrating alarmStandard
MotionAlert featureStandard
InstantAlert featureStandard
Display size1.79″ x 1.39″ high contrast, back-lit
Display optioncolor/monochrome
Backlightdisplay time adjustable
BatteryRechargeable Li-ion or Alkaline
Run time15 hrs @ room temperature, 12+ hrs for IR version @ room temperature
Charging time<= 6 hrs
Operating
temperature range
-20 ºC to +50ºC
Humidity15 – 90% RH non-condensing
Ingress protectionIP65
Data log> 200 hrs
Event log> 1000 events
Warranty2 years under normal use conditions for LEL/O2/CO/H2S versions
CertificationsCE ATEX I I 2G
Ex ia d IIC T4 –20°C to +50°C
UL Class I, Division 1, ABCDFG, Class II, Class III
CSA C22.2 No. 157 Class I, Div. 1, Groups ABCD
ANZ Ex ia s I/IIC T4 (Zone 0) -20˚C to +50˚C
IEC Ex ia d e I/IIC T4 -20˚C to +50˚C

Gases and Ranges

GasRangeSensor typeResolution
LEL0-100%Catalytic combustible1% LEL
O20-25% VolElectrochemical0.1% Vol
CO0-999 PPMElectrochemical1 PPM
H2S0-200 PPMElectrochemical1 PPM
SO20-20 PPMElectrochemical0.1PPM
Cl20-20 PPMElectrochemical0.1PPM
NH30-100 PPMElectrochemical0.5PPM
PH30-5 PPMElectrochemical0.1PPM
*HCN0-30 PPMElectrochemical0.1PPM
ClO20-1 PPMElectrochemical0.01PPM
NO20-20 PPMElectrochemical0.1PPM
CO20-10% VolIR0.01% Vol
CO20-50% VolIR0.1% Vol
CH40-25% VolIR0.2% Vol
C3H80-100% LELIR1% LEL
C3H80-100% VolIR1% Vol
C4H100-25% VolIR0.1% Vol
*C4H100-100% VolIR1% Vol

 

 

Videos

Download

Reviews

There are no reviews yet.

Be the first to review “MSA Altair 5X Gas Detector up to 6 gases”

You may also like…

Phone: 024 668 13586
Fax: +84 024 6675 4433
ANHVUCorporation
905 C6-K2, My Dinh 1, HN
Thibft kế web bởi Hoangweb.com