Introduce video BW Clip SO2 by Honeywell

Untitled-2.jpg

BW Clip SO2 by Honeywell The BW Clip Series of maintenance-free detectors are the most user-friendly, reliable and cost-effective way to ensure safety, compliance and productivity; just turn on the device and it runs continuously — no need for sensor and battery replacement or battery charging. That means great reliability and no downtime. With an

More

Single gas detector GasAlert Extreme, option: H2S; NO; CO; HCN; O2; Cl2; SO2; ClO2; PH3; O3; NH3; ETO; NO2

Hinh-anh-thu-nho-1.jpg

Single gas detector GasAlert Extreme, option: H2S; NO; CO; HCN; O2; Cl2; SO2; ClO2; PH3; O3; NH3; ETO; NO2 With easy on/off operation, this single gas detector offers extended longevity with a two year field-replaceable battery and sensor. Calibration is a simple automatic procedure and is compatible with BW Technologies by Honeywell’s MicroDock II automatic

More

Multi-gas detector GasAlertMicroClip X3 – Video 1: Intro

Untitled-1.jpg

Multi-gas detector GasAlertMicroClip X3 This is next generation from GasAlertMicroClip XL. Portable multi-gas detector GasAlertMicroClip X3 equipped new O2 sensor with longlife up to 5 years. Meanwhile, GasAlertMicroClip XL stills an economic choice with ~2 years O2 sensor. Model GasAlertMicroClip X3 also use the same design with elder generation GasAlertMicroClip XL which evaluated compact, lightweight

More

No. 5 – Calibration BW GasAlertMicroClip XL gas detector

No.-5-Hướng-dẫn-hiệu-chuẩn-Máy-đo-khí-BW-GasAlertMicroClip-XL.jpg

Calibration BW GasAlertMicroClip XL Prepare Calibration equipment: 1 Valid date gas cylinder, content: 25ppm H2S, 100ppm CO, 2.5%CH4 (50%LEL), 18% O2 Ballance N2. 1 Valve regulator 0.5L/M 1 30cm Tubing 1 Calibration cap for GasAlertMicroClip XL Step by Step: Calibration job in fresh air area Fully charged Step 1: Turn ON gas detector and let

More

No. 4 – Zero calibration for GasAlertMicroClip XL

Zero-GasAlertMicroClip-XL.jpg

Zero calibration When We need Zero Calibration? Use a gas detector for detect over measuring range. Gas sensor may poisoned. Test GasAlertMicroClip XL by non-gas standard ie: Lighter, cigarette, gas kitchen…. Where can be doing Zero Calibration GasAlertMicroClip XL In fresh air; No flammable gas, no toxic, Oxygen concentration around 20.9%VOL Performance: Turn ON unit,

More

No. 3 – How to Bump test GasAlertMicroClip XL

How-to-bump-test-a-MicroClip-XL.jpg

Bump test GasAlertMicroClip XL What is Bump test a gas detector? Bump test is checking responsibility of gas sensors and alarm trigger checking. Why need Bump test? We need ensure that detector still work well before use, because it is safety equipment. Almost maker recomment user doing Bump test each day before use. Prepare for

More

No. 2 – Turn ON/OFF 4 gases detector GasAlertMicroClip XL

No-2.-Bat-Tat-GasAlertMicroClip-XL.jpg

Turn ON/OFF 4 gases detector GasAlertMicroClip XL Generally, Turn ON/OFF a 4 gases detector are the same way, only manipulation are diffrent between a maker The general principle of turning on a gas detector is as follows: Fully charging before use. If low battery, some function may work in-correct. Press and hold Power button until unit

More

No. 1 – Introduction video for GasAlertMicroClip XL

No-1.-Gioi-thieu-GasAlertMicroClip-XL.jpg

GasAlertMicroClip XL gas detector BW Honeywell GasAlertMicroClip XL portable multi-gas detector is 4 gases detector, it can be detect LEL/O2/CO and H2S simultaneously. And it also the most popular 4 gases detector in the world. This is personal monitor for protect a personal (one man wear one piece). It is diffrent with a confined space detector

More

BW GasAlertMax XT II – No. 5: Zero Calibration

Zero-BW-GasAlertMax-XT-II.jpg

Zero Cal. for GasAlertMax XT II Why We need Zero Calibration? The sensor of the gas detector will automatically drifting over time, it will faster drift when use unit in much toxic environment. Gas sensors can be poisoned when the user use this unit in an over-range concentration. How to Zero calibration GasAlertMax XT II

More