CAC-Gas Mixers & Gas Diluters

0 Comments
CAC-Nomad

CAC Gas provides multiple solutions for creating on-site customized gas standards. Software controlled, the GasMix line is based on mixing, diluting and injecting two to twelve gas standards. Easy to use, GasMix™ is a versatile tool for laboratory, environmental or industrial application.

CAC-HURRICANE

  • Number of gas channels: 5 to 16 (possibility up to 20)
  • Inlet Gas Pressure: 3 bars nominal, max 8 bars
  • Outlet Pressure: atmospheric, higher on request
  • Connections: Swagelok 1/8”,other on request
  • Gas compatibility: pure gases, concentrated gas mixtures, most of aggressive and reactive gases (for specifics, contact us)
  • Mixing: mixing up to 20 channels simultaneously
  • Dilution ratio of the initial concentration: up to 1:10000
  • MFC operation range: 2 to 100% FS
  • Flow accuracy: ±1% of setpoint all over the scale
  • Repeatability: less than 0.1% of setpoint
  • Response time to the setpoint <5 sec
  • Software: PC Windows 7 or higher, Ethernet port communication Optional: – Automatic regulation of output flow – Heated tubing for specific gases
  • Operation temperature: 10-50°C
  • Power supply: 90-260Vac, 1,5-4A, 50-60Hz
  • Dimensions: Lxlxh (cm) : 66x45x17
  • Weight: approx. 25 kg (depends on configuration)

CAC-AIOLOS II

  • Number of gas channels: 2 to 4
  • Inlet Gas Pressure: 3 bars nominal, max 8 bars
  • Outlet Pressure: atmospheric, higher on request
  • Connections: Swagelok 1/8”, other on request
  • Gas compatibility: pure gases, concentrated gas mixtures, most of aggressive and reactive gases (for specifics, contact us)
  • Mixing: mixing up to 4 channels simultaneously
  • Dilution ratio of the initial concentration: up to 1:10000
  • MFC operation range: 2 to 100% FS
  • Flow accuracy: ±1% of setpoint all over the scale.
  • Repeatability: less than 0.1% of setpoint
  • Response time to the setpoint <5 sec
  • Software: required PC with Windows 7 or higher, Ethernet port communication
  • Operation temperature: 10 – 50°C
  • Power supply: 90-260Vac, 1,5-4A, 50-60Hz
  • Dimensions: L x l x h (cm): 43x25x46.
  • Weight: approx. 14 kg (depends on configuration)

CAC-ATMO

  • Number of gas channels: 3
  • Inlet Gas Pressure: 3 bars nominal, max 8 bars
  • Number of outlet gas channels: 3
  • Outlet Pressure: atmospheric
  • Connection: 1/8” Swagelok – 1/4” for the diluent gas
  • Gas compatibility: pure gases, non-aggressive gases
  • Dilution ratio of the initial concentration: up to 1:10000
  • MFC operation range: 2 to 100% FS
  • Flow accuracy: ±1% of setpoint all over the scale.
  • Repeatability: less than 0.1% of setpoint
  • Software: PC Windows 7 or higher, Ethernet port communication Optional 19’’ rack housing
  • Operation temperature: 10 – 50°C
  • Power supply: 90-260Vac, 1,5-4A, 50-60Hz
  • Dimensions: L x l x h (cm): 42 x 22 x 46;
  • Weight: 16 kg

CAC-AURA II

  • Inlet Pressure max: 50 bar (725 psi), protected by relief valve.
  • Inlet Pressure min: 2 bar (30 psi)
  • Vaporizer temperature: max 160°C (320°F)
  • T° regulator range: 40-160°C (104-320°F)
  • Warm Up time: Typical 15 minutes
  • Heat power of vaporizer: 100W
  • Internal gas lines: Heated at 120°C (248°F)
  • Output gas line: Insulated transfer line of 1 meter, heated at 120°C (248°F)
  • Inlet filter: stainless steel, 0.5µ
  • Output regulation: Pressure or Flow
  • Outlet Pressure: typical 1 bar abs (14psi), max 3 bar (43psi)
  • Output Flow: 20 to 200 ccmin (methane)
  • Power supply: 24VDC, external AC-DC adapter
  • Electrical specification: 110-230VAC, 2.4A, 50-60Hz
  • Connectors: 1/8″ inlet; 1/8″ output line; 1/4″ to vent
  • Inert lines: Entire gas flow path is inert treated compatible with trace analysis of reactive analytes.
  • Regulators: Temperature, Pressure, Flow
  • Indicators: Power On, Heat Lines On, Regulating
  • Dimensions: 22x27x31 cm (8.6” x 10.6” x 12.2”)
  • Weight: 8 kg (18 lbs)
  • Note: Specifications subject to change without notice

CAC-ZEPHYR

  • Number of gas channels: 2
  • Inlet Gas Pressure: 3 bars nominal, max 8 bars
  • Outlet Pressure: atmospheric, higher on request
  • Connections: Swagelok 1/8”, other on request
  • Gas compatibility: In standard with Kalrez seals, stainless steel 316 tubing with inert coating. Compatible with most aggressive gases and active compounds like trace sulfurs, NO2, ammonia, VOC (for specific cases, please contact us)
  • Dilution ratio of the initial concentration: 1:2000 in standard /up to 10000 max
  • MFC operation range: 2 to 100% FS
  • Flow accuracy: ±1% of setpoint all over the scale.
  • Repeatability: less than 0.1% of setpoint
  • Response time to the setpoint <5 sec
  • 5” Color touch screen
  • Embedded dedicated Ze Soft software.
  • Power supply: 90-260Vac, 1,5-4A, 50-60Hz
  • Optional: NiCad rechargeable battery autonomy 8h
  • Operation temperature: 10-50°C
  • Dimensions : L x l x h (cm) : 38 x 16 x 26; Weight: 6,5kg
  • * Note: Specifications subject to change without notice

CAC-NOMAD

  • Number of gas channels: 3 to 4
  • Inlet Gas Pressure: 3 bars nominal, max 8 bars
  • Outlet Pressure: atmospheric, higher on request
  • Connections: Swagelok 1/8”, other on request
  • Gas compatibility: pure gases, concentrated gas mixtures, most of aggressive and reactive gases (for specifics, contact us)
  • Mixing: mixing up to 4 gases simultaneously
  • Dilution ratio of the initial concentration: up to 1:10000
  • MFC operation range: 2 to 100% FS
  • Flow accuracy: ±1% of setpoint all over the scale
  • Repeatability: less than 0.1% of setpoint
  • Response time to the setpoint <5 sec
  • Software: delivered with GasMix 3.1
  • USB mouse and keyboard in option Remote connection Ethernet
  • Operation temperature: 10 – 50°C
  • Power supply: 24VDC provided with AC adapter
  • Dimensions: L x l x h (cm): 43x32x24;
  • Weight: approx. 10 kg
  • * Note: Specifications subject to change without notice

CAC-GMRACK

  • Number of gas channels: 2 to 4
  • Inlet Gas Pressure: 3 bars nominal, max 8 bars
  • Outlet Pressure: atmospheric, higher on request
  • Connections: Swagelok 1/8”, other on request
  • Gas compatibility: pure gases, concentrated gas mixtures, most of aggressive and reactive gases (for specifics, contact us)
  • Mixing: mixing up to 4 channels simultaneously
  • Dilution ratio of the initial concentration: up to 1:10000
  • MFC operation range: 2 to 100% FS
  • Flow accuracy: ±1% of setpoint all over the scale.
  • Repeatability: less than 0.1% of setpoint
  • Response time to the setpoint <5 sec
  • Build-in computer with touch screen panel 5.’’
  • Software: Embedded software + standard GasMix™ PC software provided On-site upload/download projects via USB port
  • Can be remotely controlled via Ethernet link I/O relay or TTL communication with an external analyze Optional: –
    • Automatic regulation of output flow
    • Heated tubing for specific gases
    • Customized communications options
  • Operation temperature: 10-50°C
  • Power supply: 90-260Vac, 1,5-4A, 50-60Hz
  • Dimensions: L x l x h: 48.3×34.5×18 cm (19“x13.6“x7“)
  • Weight: approx. 9 kg (depends on configuration)
  • * Note: Specifications subject to change without notice

CAC- LIQMIX CASCADE

  • Number of liquid channels: 1
  • Liquid MFC Coriolis technology, from 5g/h to 200 g/h FS
  • Liquids: Pure liquid or a liquid mixture (ex.: water, organic solvents) without precipitation, polymerization or salt formation (for specifics, please contact us)
  • Liquid flask (optional) should be pressurized by inert gas
  • Number of gas channels: up to 5
  • Inlet Gas pressure: stable and regulated within 3-8 bar
  • Gas compatibility: pure gases, concentrated gas mixtures, most of aggressive and reactive gases (for specifics, contact us)
  • Dilution ratio of the initial concentration on 1st stage: up to 1:10000
  • Accuracy: less than 2% all over the scale 2nd stage (Cascade)
  • Number of gas channels: 1
  • Dilution ratio of the initial concentration on 2nd stage up to 1:10000
  • MFC operation range: 2 to 100% FS
  • Flow accuracy: ±0.5% of setpoint all over the scale
  • Repeatability: less than 0.1% of setpoint
  • Overall dilution ratio of 2 stages: up to 108
  • Heated output line length 2m in standard
  • Outlet Gas Pressure: atmospheric, higher pressure possible
  • Connectors: Swagelok 1/8”, other on request
  • Software: required PC with Windows 7 or higher, Ethernet port communication
  • Operation temperature: 10-50°C
  • Power supply: 90-260Vac, 1,5-4A, 50-60Hz
  • Dimensions: L x W x H 42x47x46 cm
  • Weight: approx. 35 kg (depends on configuration)
  • Note: Specifications subject to change without notice

Data Sheets

Video