Drager Pac 7000 Personal Gas Detector with many gases option

16,500,000

Please note: this product is now obsolete. See the Drager Pac 6500 as an alternative product.

Drager-logo-150x150

Description

The Pac 7000 from Draeger is a reliable personal gas monitor which can be used to detect harmful concentrations of many toxic gases.  It can be used industrial settings.

This small detector is highly reliable and will provide you with fast and accurate results when detecting gas.

The Pac 7000 has the ability to carry out long-term operations and has an automated bump test process which makes testing easier.  This requires the use of the Draeger Bump Test Station.  Bump tests are configurable and can match specific safety regulations.

Another feature of this Drager monitor is the automatic shut-off function. This ensures the instrument shuts down after a set period of time if function tests have not been carried out.

KEY FEATURES

  • Impact-resistance and protective rubber coating – impervious to corrosive chemicals
  • Optimised protection against electromagnetics
  • Fasten monitor to clothing using adjustable crocodile clips
  • Replaceable water and dust filter, battery and sensor – can be done onsite without additional equipment
  • Gas hazards are displayed immediately
  • Adjustable data logger records all concentrations and events with respective dates and times (120 hours @ 1 data set per minute)
  • Data is downloadable via Drager Pac Vision, CC-Vision or GasVision software
  •  Integrated menu for calibration options
  • Password protection option for fresh air or span calibration
  • Gas Inlets at the top and front of device
  • Automated bump test process with Drager Bump Test Station

Brand

Drager (Draeger)

Drager (Draeger) portable gas detectors offer precise, reliable and multifunctional measurement of harmful gases. The portable gas detectors are used for diverse applications like personal workplace monitoring, clearance measurement of confined spaces, leakage detection, area monitoring and many more. Drager (Draeger) portfolio of handheld gas detectors contains single-gas and multi-gas detectors, gas detector tubes as well as calibration and bump testing equipment and software packages.

Drager (Draeger) single gas detector range: Dräger Pac® 6000, Dräger Pac® 6500, Dräger Pac® 8000, Dräger Pac® 8500, Dräger X-am® 5100

Drager (Draeger) Multi-gas detector range: Dräger X-pid® 8500, Dräger X-am® 8000, X-site Live, Dräger X-am® 3500, Dräger X-am® 5000, Dräger X-zone® 5500, Dräger X-am® 2500, Dräger X-am® 5600 Personal Monitor

Drager-logo-150x150

Specification

Drager Pac 7000 – Product Range

Part Ref Measuring Range Default Alarm Threshold A1/A2 Resolution Response
Pac 7000 H2S 0 – 100ppm 10/20ppm 1ppm 15 seconds
0 – 100ppm By request 1ppm 15 seconds
Pac 7000 H2S Low Concentrations 0 – 100ppm By request 0.1ppm 15 seconds
Pac 7000 O2 0 – 25 Vol-% 19/23% 0.1 Vol-% 10 seconds
0 – 25 Vol-% 19.5/23.5% 0.1 Vol-% 10 seconds
0 – 25 Vol-% By request 0.1 Vol-% 10 seconds
Pac 7000 CO 0 – 1999ppm 30/60ppm 1ppm 15 seconds
0 – 1999ppm 35/50ppm 1ppm 15 seconds
0 – 1999ppm By request 1ppm 15 seconds
Pac 7000 CO2 0 – 5 Vol-% By request 0.1 Vol-% 30 seconds
Pac 7000 SO2 0 – 100ppm By request 1ppm 15 seconds
Pac 7000 CL2 0 – 20ppm By request 0.05ppm 30 seconds
Pac 7000 HCN 0 – 50ppm By request 0.1ppm 15 seconds
Pac 7000 NH2 0 – 300ppm By request 1ppm 20 seconds
Pac 7000 NO2 0 – 50ppm By request 0.1ppm 15 seconds
Pac 7000 NO 0 – 200ppm By request 1ppm 15 seconds
Pac 7000 PH2 0 – 20ppm By request 0.01ppm 10 seconds
Pac 7000 OV 0 – 200ppm By request 0.5ppm 100 seconds
Pac 7000 OV-A 0 – 200ppm By request 1ppm 100 seconds
Pac 7000 5Y H2S 0 – 100ppm By request 1ppm 15 seconds
Pac 7000 5Y O2 0 – 25 Vol-% By request 0.1 Vol-% 10 seconds
Pac 7000 5Y CO 0 – 1999ppm By request 1ppm 15 seconds

Drager Pac 7000 – Technical Specification

Dimensions 84mm x 64mm x 25mm; 3.3″ x 2.5″ x 1.0″ (Width x Height x Depth)
Weight 120g; 3.8oz
Ambient Conditions Temperature: -30ºC to +50ºC; -20ºF to +120ºF / Pressure: 700 – 1300 hPa / Humidity: 10 – 90% r.h / Note: (Pac 7000 CO2 has a temperature range of -20ºC to +40ºC; -4ºF to +104ºF) & (Pac 7000 HCN and PH2 have a temperature range of -20ºC to +50ºC; -4ºF to +120ºF)
Ingress Protection IP65
Display Language-free LCD display, continuous indication of concentration, peak concentration, TWA- and STEL-concentration, operating time, notice and alarm functions
Typical Battery Life 5500 hours (O2 version – 2700 hours)
Acoustic Alarm Two-tone-alarm, typical > 90 dB at a distance of 30cm
Data Logger Storage of concentration and events with date and time (120 hours at 1 data set per minute)
Certification CE Sign: (89/336/EEC, 94/9/EC)

ATEX: II 1 G EEx ia IIC T4, I M 1 EEx ia I T 4

UL: Class I, II, Div 1, Group A, B, C, D, E F, G, Temp Code T4

cUL: Class I, II, Div 1, Group A, B, C, D, E, F, G, Temp Code T4

IECEx: EEx ia IIC, T4

Marine Equipment Directive: 96/98/EC

Measurement Performance Certificate (according to ATEX) EN45544 (CO, H2S), EN50104 (O2), EN 50271

 